FlexiROC T30 R 13 Electrical System
96 No: 3629357835.1.3629419915 en-US
Precondition
p
Switch off the RCS system on the control system panel.
p
Disconnect fire-fighting system.
1.
Check that the auxiliary batteries (A) have the same voltage as the chassis batteries
(B).
2.
Connect the positive terminal of the auxiliary batteries (A) to the positive terminal of
the chassis batteries (B).
3.
Connect the negative terminal of the auxiliary batteries (A) to ground on the chassis.
!
NOTE: Do not connect the negative terminal of the auxiliary batter-
ies (A) to the chassis batteries (B) negative terminal.
4.
Disconnect the cable from the chassis ground as soon as the engine starts.
5.
Disconnect the cable from the negative terminal on the auxiliary batteries (A).
6.
Disconnect the cable between the positive terminal of the chassis batteries (B) and
the auxiliary batteries (A).