Safety Instructions
12
Do not use any devices that generate high frequencies near the unit.
Using electric surgical knives, mobile phones, or other devices that generate high frequencies near the unit
may cause malfunctions due to jamming.
Ensure the unit is securely grounded when connecting the unit to a power source.
This can prevent electric shock due to current leakage. In order to complete the ground connection, be sure to
connect the power plug to a three-prong, correctly grounded outlet. Do not operate the unit if you have any
doubts about its ground connection.
Ensure the peripheral electrical equipment is securely grounded when connecting the unit
to a power source.
Take care of the usage environment.
Using the unit in a strong electromagnetic environment may disrupt accurate control over the incubator air
temperature or prevent accurate skin temperature from being displayed.
Do not use the unit next to other devices.
Using the unit next to or stacked with other devices may cause malfunction.
When it is unavoidable to do so, it is necessary to check that the unit and the other devices are operating cor-
rectly.
Avoid damaging the power cord.
A damaged power cord may cause a fire or electric shock. If a power cord is damaged, it should be immediately
replaced with a new one.
z
Do not allow the power cord to get caught between the unit and wall, shelf or floor.
z
Do not place the power cord near a heating apparatus or heat it.
z
Do not place any heavy objects on the power cord.
z
Always grasp the power plug with your hand to remove the power cord from the power outlet.
Use only the power cord supplied with the unit.
Otherwise, a fire or an electric shock may result. A power cord or an AC adapter other than the one supplied
with the unit can generate high frequency noise and cause jamming to other electric devices for medical use
and thus result in malfunction, or make the unit more susceptible to high frequency noise emitted by other
electrical devices and thus result in malfunction.
Do not put multiple loads on one power outlet.
The power outlet should be located near the unit in order to prevent accidental contact with a trailing power
cord. Use a separate power outlet for each unit.
Avoid connecting the unit to a power source other than a appropriately rated power source.
The electrical rating of this unit is as follows:
Power voltage - AC100-240V; frequency - 50/60Hz; power consumption - 220VA; operating voltage range
-AC100-240V±10%. Do not connect the unit to any other power source.
Do not touch the power plug with wet hands.
Touching the power plug with wet hands may cause electric shock.
Do not use a battery that has reached the end of its service life.
The unit uses a battery that has a limited life span. If the battery is used past its life span of two years, not only
will it no longer function, but it may also short the electronic circuits inside or cause other damages to the bat-
tery, which may result in smoke or fire.
If the battery is subjected to a shock, it may also cause smoke or fire. If it happens, stop using or recharging
the battery, and contact your local Atom representative immediately.