Version 7.2 933 Mediant 1000B Gateway & E-SBC
User's Manual 62. Configuration Parameters Reference
Parameter Description
ï‚§
[1] = Enable
configure system > snmp settings >
sys-oid
[SNMPSysOid]
Defines the base product system OID.
The default is eSNMP_AC_PRODUCT_BASE_OID_D.
Note: For the parameter to take effect, a device reset is
required.
[SNMPTrapEnterpriseOid] Defines the Trap Enterprise OID.
The default is eSNMP_AC_ENTERPRISE_OID.
The inner shift of the trap in the AcTrap subtree is added to
the end of the OID in the parameter.
Note: For the parameter to take effect, a device reset is
required.
[acUserInputAlarmDescription] Defines the description of the input alarm.
[acUserInputAlarmSeverity] Defines the severity of the input alarm.
[AlarmHistoryTableMaxSize] Defines the maximum number of rows in the Alarm History
table. The parameter can be controlled by the Config Global
Entry Limit MIB (located in the Notification Log MIB).
The valid range is 50 to 1000. The default is 500.
Note: For the parameter to take effect, a device reset is
required.
configure system > snmp settings >
engine-id
[SNMPEngineIDString]
Defines the SNMP engine ID for SNMPv2/SNMPv3 agents.
This is used for authenticating a user a
ttempting to access the
SNMP agent on the device.
The ID can be a string of up to 36 characters. The default is
00:00:00:00:00:00:00:00:00:00:00:00 (12 Hex octets
characters). The provided key must be set with 12 Hex values
delimited by a colon (":") in the format xx:xx:...:xx. For
example, 00:11:22:33:44:55:66:77:88:99:aa:bb
Note:
ï‚§ For the parameter to take effect, a device reset is required.
ï‚§ Before setting the parameter, all SNMPv3 users must be
deleted; otherwise, the parameter setting is ignored.
ï‚§ If the supplied key does not pass validation of the 12 Hex
values input or it is set with the default value, the engine
ID is generated according to RFC 3411.
SNMP Trap Destination Parameters (configure system > snmp trap destination)
Note: Up to five SNMP trap managers can be defined.
SNMP Manager
[SNMPManagerIsUsed_x]
Determines the validity of the parameters (IP address and
port number) of the corresponding SNMP Manager used to
receive SNMP traps.
ï‚§ [0] (Check box cleared) = Disabled (default)
ï‚§ [1] (Check box selected) = Enabled
IP Address
ip-address
Defines the IP address of the remote host used as an SNMP
Manager. The device sends SNMP traps to this IP address.

Table of Contents

Other manuals for AudioCodes MSBG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBG Series and is the answer not in the manual?

AudioCodes MSBG Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBG Series
CategoryGateway
LanguageEnglish

Related product manuals