4
References
Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
ACK NAK Retry
Count
This feature specifies the number of times the reader retries a label transmission due to a retry
condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a
selection of 255 specifies unlimited retries.
To set this feature:
1 Determine the desired setting.
2 Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 =
020, etc.
3 Go to page 41 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Pro-
gramming Mode.
4 Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING.
5 Scan the appropriate three digits from the keypad in Appendix D: Keypad, that represent the
number which was determined in the steps above. You will hear a two-beep indication after
the last character.
6 Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See Table ACK NAK Retry Count Setting Examples for some
examples of how to set this feature.
ACK NAK Retry
Count Setting
Examples
NOTE
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the beginning.
STEP ACTION EXAMPLES
1 Desired Setting
Disable Retry
Count
3 Retries 54 Retries Unlimited Retries
2
Pad with leading
zero(es)
000 003 054 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT ACK NAK RETRY COUNT SETTING
5
Scan Three
Characters From
Appendix D: Keypad
‘0’, ‘0’ and
‘0’
‘0’, ‘0’ and
‘3’
‘0’, ‘5’ and
‘4’
‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE