80
3
Configuration Using Barcodes
Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
Reading Active
Time
This setting specifies the amount of time that the reader stays in scan ON state once the state is
entered. The range for this setting is from 1 to 255 seconds in 1-second increments. See
page 263 in “References” for further description of this feature.
Stand
Illumination
Control
Controls the illumination status while the reading mode is stand mode and the reader is attempt-
ing to detect objects.
Reading Active Time = 3 seconds
Reading Active Time = 5 seconds
Reading Active Time = 8 seconds
CSNET03(CR
CSNET05(CR
DEFAULT
CSNET08(CR
Stand Illumination Control = OFF
Stand Illumination Control = ON
Stand Illumination Control = Dim
DEFAULT
CSMIL00(CR)
CSMIL01(CR)
CSMIL02(CR)