14. Preventative maintenance actions
14.2 3 month maintenance actions
MAINTENANCE TYPE B (perform every three months)
The 3 mo nth maintenance actions, listed below, may be perform ed by a trained projectionist who is familiar
with potential hazards associated with the product.
No. Maintenance a ction Remarks
1
Clean the back air outlet vents of the lam p modules and L amp Powe r Supply
(LPS).
Dust the vents using a vacuum cleaner
with br ush attachment.
2
Clean the housing of your projector.
Remove excess dus t on and around
the projector covers. See cleaning
instructions in this manual.
3
Verify the internal c lock of the ICMP with real time clock. Correct if needed. ICMP version 1.2.1 is required.
Comm unicator version 5.0 is required.
See user guide of C omm unicator for
detailed instructions.
4
Check the lamp module compartment and lamp fan for dust. Clean if necessary. Use a vacuum
cleaner with brush attachment to
remove dust.
R5906693 DP2K-E SERIES 19/06/2015 109