8. ICMP
8.8 ICMP conguration v ia Communicato r
About ICMP conguration
Following parameters are available to congure the ICM P:
Global settings: allows dening name of the IC MP, host nam e (network identier) and IP address which can be used for com-
munication with external content devices.
U ser settings: denition o f all users allowed on the ICMP.
Ser ver settings: denition of access to servers and storage libraries of content (mov ies, K D M, etc.).
Player settings: Aud io de lay and audio output frequency.
Audio channel: allows dening the mapping of audio channels (content) on each audio output (AES outputs of the ICMP ).
Scheduler setting: Enable/Disable scheduler at startup, delays allowed in scheduler m ode and length of schedule history.
Devices: allows d e ning commun ication ports s ettings, to access external devices c ontrolled by the automation.
Automation Cues: event cues that are triggered from different sources and to which can be assigned actions to be executed
by the autom ation engine.
Verify internal clock of the ICMP.
All installation and maintenance operations on the ICMP are performed via Communicator, the Barco cong-
uration software. Please refer to the Commu nicator user g uide for further information.
About Default settings
The restore of factory setting is a feature that allows removing all settings performed on the ICMP and replaces them with the default
values set at t he factory. Please refer to the Comm unicator user gu ide for further inform ation.
About the ICMP internal clock
The crystal on the ICMP board that manages the clock shows a certain drift (all crystals do). With the Com m unicator the internal
clock can be adjusted. T his maintenance action should be repea ted every 3 months. Wh en neglected the system will locks up.
From ICM P software version 1.2.1 onwards it is possible to enable N TP (Network Time Protocol). You have to con gure (at instal-
lation) an IP address where the ICMP can nd a s ync signal. From then on, and as long as the connection is ac tive, the ICMP will
automatically keep its clock correct. For detailed instructions s ee user guide of the Communic ator.
R5906693 DP2K-E SERIES 19/06/2015
63

Table of Contents

Other manuals for Barco DP2K-E series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco DP2K-E series and is the answer not in the manual?

Barco DP2K-E series Specifications

General IconGeneral
BrandBarco
ModelDP2K-E series
CategoryProjector
LanguageEnglish

Related product manuals