Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
160
of 208
A
P1160 Keypad potentiometer gain 0.1 to 100.0 % 100.0 % 1:1 108
P1161 Keypad potentiometer negative enable/disable 0 to 1 0 1:1 108
P1162 Analog output signal (AFM) 0 to 1 0 1:1 108
P1163 Analog output gain 1 to 200 % 100 % 1:1 109
P1164 AO1 terminal mode selection 0 to 2 0 1:1 109
P1165 Analog output signal AO1 0 to 1 0 1:1 110
P1166 Analog output gain AO1 0 to 200 % 100 % 1:1 110
P1167 AO2 terminal mode selection 0 to 2 0 1:1 110
P1168 Analog output signal AO2 0 to 1 0 1:1 111
P1169 Analog output gain AO2 0 to 200 % 100 % 1:1 111
P1170 Ramp function generator mode 0 to 120 0 1:1 112
P1171 Display ramp function generator input 0.0 to 600.00 Hz 0.00 Hz 100:1 112
P1172 RFG acceleration time 1 0.1 to 600.0 s or
0.01 to 60.00 s
10.0 s 10:1 or
100:1
112
P1173 RFG deceleration time 1 0.1 to 600.0 s or
0.01 to 60.00 s
10.0 s 10:1 or
100:1
113
P1174 RFG quickstop time 0.1 to 600.0 s or
0.01 to 60.00 s
10.0 s 10:1 or
100:1
113
P1176 RFG S-curve accel time 0.1 to 600.0 s or
0.01 to 60.00 s
10.0 s 10:1 or
100:1
113
P1177 RFG S-curve decel time 0.1 to 600.0 s or
0.01 to 60.00 s
10.0 s 10:1 or
100:1
114
P1180 RFG ramp-up time 2 0.1 to 600.0 s or
0.01 to 60.00 s
10.0 s 10:1 or
100:1
115
P1181 RFG ramp-down time 2 0.1 to 600.0 s or
0.01 to 60.00 s
10.0 s 10:1 or
100:1
115
P1182 RFG jog ramp-up time 0.1 to 600.0 s or
0.01 to 60.00 s
10.0 s 10:1 or
100:1
115
P1183 RFG jog ramp-down time 0.1 to 600.0 s or
0.01 to 60.00 s
10.0 s 10:1 or
100:1
115
P1184 RFG jog frequency 0.10 to 600.00 Hz 6.00 Hz 100:1 s 116
P1185 RFG Auto acceleration/deceleration 0 to 4 0 1:1 117
P1186 RFG accel/decel time unit 0 to 1 0 1:1 118
P1187 Ramp function generator status 0 to 65535 0 1:1 119
P1188 RFG output 0.00 to 600.00 Hz 0.00 Hz 100:1 119
P1189 1st step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 119
P1190 2nd step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 119
P1191 3rd step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 120
P1192 4th step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 120
P1193 5th step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 120
P1194 6th step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 120
P1195 7th step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 120
P1196 8th step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 121
P1197 9th step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 121
P1198 10th step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 121
P1199 11th step speed frequency 0.00 to 600.00 Hz 0.00 Hz 100:1 121
Parameter Range Standard value Internal
standard-
ization
Page