EasyManua.ls Logo

Baumuller b maXX 5000 Series - 7.10 Avoid bearing currents

Baumuller b maXX 5000 Series
330 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Avoid bearing currents
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
138
of 328
7.10
Locking torque of the fixing screw:
Device Locking torque
Single axis unit BM5326, BM5327, BM5328 0.8 Nm
cable diameter 5 - 20 mm
sh
ielding clamp width 24 mm
Double axis unit BM5323, BM5325 0.8 Nm
cable diameter 3 - 14 mm
sh
ielding clamp width 17 mm
Single axis unit BM5334, BM5335,
BM537X, connection 2 x 16 mm²
1 Nm
cable diameter 5 - 28 mm
sh
ielding clamp width 31 mm
Double axis unit BM5331, BM5332, BM5333
Single axis unit BM537X, connection 50 mm² 1.5 bis 1.8 Nm
cable diameter 20 - 35 mm
sh
ielding clamp width 40 mm
7.10 Avoid bearing currents
NOTE
The pulsed output voltage of a converter cau
ses additional motor bearing currents.
Bearing currents cause localized
melting on ball race and rolling body as well as wear
of the lubricant. This leads to a reduced service life of the bearing.
Bearing currents depend on:
m Mo
tor speed
m Switc
hing frequency of the converter
m Gro
unding
Furthermore the height of the bea
ring currents depends on:
m the
applied bearing voltage
m th
e dielectric characteristic of the bearing lubrication
NOTE
The reduction of bearing currents requires the consideration of the whole speed-
variable drive system and its installation!
Baumüller supports you with on-site measurements and with development and imple-
mentation of suitable pr
eventative measures.