11.1.9.5 Connecting cable for sine/square-wave incremental encoder
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a
self-made cable is to be used:
1 Utilize the following materials:
m C
able: Li9YC3x2x0.25-Li9Y3x2x0,25-Li9Y C11Y 1x2x0.34GN. Two cable pairs are
not needed and also not connected.
m Hig
h-density D-sub connector: 26-pin, male
m Ro
und connector: 12-pin, female (e.g. from Interconnectron)
2 Fully adjoin the cable shield with the housing
of the round connector and with the
shielding of the D-sub connector.
5000_1103_rev01_int.cdr
2
1
4
5
6
8
9
12
11
17
18
7
12
10
5
6
8
3
4
2
11
7
9
1
Æ 0.34 mm
Æ 0.34 mm
Figure 113: Connecting cable for sine/square wave incremental encoder
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not functionally operable and could
le
ad to defects, both in the encoder module and the encoder!