4.4
4.4.4 LED display fieldbus
LED EtherCAT
®
. Type code
BM5XXX-XXXX-XXXX-01XX
BM5XXX-XXXX-XXXX-07XX
Naming on the
front plate
H31 (green) X3 Link / Act Off: No connection
On: Connection
Blinking: Data transfer
H32 (yellow) ERROR On: ERROR (receiver error Phy1/Phy2)
H41 (green) X4 Link / Act Off: No connection
On: Connection
Blinking: Data transfer
H42 (yellow) RUN Off: ERROR/INIT
500 ms on /
500 ms off: PREOPERATIONAL
200 ms on /
1 s off: SAFEOPERATIONAL
On: OPERATIONAL
LED VARAN Type code
BM5XXX-XXXX-XXXX-02XX
Naming on the
front plate
H31 (green)
H41 (green)
LINK On: Connection between 2 PHYs
(physical interfaces) is established
H32 (yellow)
H42 (yellow)
ACTIVE On: Data is received or transmitted
LED CANopen
®
Type code
BM5XXX-XXXX-XXXX-03XX
No function
Meaning Blinking pattern
Meaning Blinking pattern