Description of the safety function STO
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
320
of 328
C.7
C.7.4 Safety function STO im BM5030-XX2X-...
The STO switch is checked by the device automatically when changing to the state ready-
to-operate.
State change from STO
Ready-to-operate (closing of the switches) is only possible if
both switches were open prior to that.
In case of the failure of one of the switches (
= closed in state STO), the device remains
in state STO. H6 lights red.
STO timing
Figure 134: STO timing BM5030-XX2X-...
t
1
maximal 5 ms

Table of Contents