Operation
Instruction handbook b maXX 5000
Document No.: 5.09021.16
205
of 328
8
8.1.2 Service interface
The service interface is used to transmit controller parameter from a PC/laptop to the con-
troller with the software ProDrive.
The mains rectifier unit BM50XX has no service interface.
h conn
ect a not used USB port of the PC/laptop with the controller via the service cable
HINWEIS!
Only the service cable BM5-K-USB-XXX is allowed to be used for the
service inter-
face X1, refer to ZService interfac
e cableon page 250.
BM51XX BM53XX
X1
Figure 90: Female connector X1
The driver for this connection has been installed with ProDrive on the PC/laptop. The set-
tings of the connection (baud rate, etc.) is done via ProD
rive. Refer to Online help of Pro-
Drive.
HINWEIS!
In case the service cable is not used, keep it in the ESD packaging.