Cabling
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
254
of 328
11.1
11.1.9.2 Connecting cable for encoder with HIPERFACE
®
.
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a
self-made cable is to be used:
1 Utilize the following materials:
m C
able: Li9YC3x2x0.25-Li9Y3x2x0,25-Li9Y C11Y 1x2x0.34GN. Two cable pairs are
not needed and also not connected.
m Hig
h-density D-sub connector: 26-pin, male
m Ro
und connector: 12-pin, female (e.g. from Interconnectron)
2 Fully adjoin the cable shield with the housing
of the round connector and with the
shielding of the D-sub connector.
5000_1102_rev01_int.cdr
2
1
4
5
6
19
20
17
18
7
12
10
8
1
5
2
7
3
4
6
Æ 0.34 mm
Æ 0.34 mm
Figure 109: Connecting cable for encoder with HIPERFACE
®
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not operable and could lead to de-
fects, both in the encoder module and the encoder!