Baumuller b maXX 5000 Series - C.6.2 Connections front side BM5030 with safety function

Baumuller b maXX 5000 Series
330 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BM5030 with Safety Function
Instruction handbook b maXX 5000
Document No.: 5.09021.16
313
of 328
B
C.6.2 Connections front side BM5030 with safety function
X1 Digital inputs / outputs
BM5030-XX2X-...
X1 Digital inputs/outputs
1:M
24V
2: Inhib
it input
3: Reserv
ed
4:
Reset
5: Error
6: Ready-to-operate
Figure 131: Connection X1 front side BM5030 with safety function
Pin assignment
Pin
No.
Assignment
1 Dig. input/output GND 24 V
2 Digital input Inhibit input
1)
BM5030-XXX0
input is high active,
expe
cts
NO contact
BM5030-XXX1
input is low active,
expe
cts
NC contact
3 Digital input Reserved
4 Digital input Reset
5 Digital output Error
6 Digital output Ready-to-operate
Input current per input 7 mA
Input level High (12 … 28 V)
Output current per output 500 mA
Output level High (12 … 28 V)

Table of Contents