EasyManua.ls Logo

Baumuller b maXX 5000 Series - 7.15.2 Front side of active mains rectifier BM51 XX

Baumuller b maXX 5000 Series
330 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
Instruction handbook b maXX 5000
Document No.: 5.09021.16
173
of 328
7
7.15.2 Front side of active mains rectifier BM51XX
X1: Service interface
NOTE!
Only the service cable BM5-K-USB-XXX is
allowed to be used for the service interface
X1, refer to ZService interfaceon page
205.
X2 Digital inputs/outputs *)
1:see Zpage 174
2 to 3: Ready for pulse-enable (SELV/PELV)
4 to 6: Digital output (SELV/PELV)
7: Ready-to-operate for PLC
8: see Zpage 174
9 to 10: Ready for main contactor on
(SELV/PELV)
11: +24V (SELV/PELV)
12: M24V (SELV/PELV)
13: Fast digital input 1 (SELV/PELV)
14: Fast digital input 2 (SELV/PELV)
15 to 17: Digital input (SELV/PELV)
18: Digital input 6/ quick discharge
19: Digital input 7/ reset errors
20: Digital input 8/ pulse enable
111
10 20
Figure 85: Connections controller part BM51XX

Table of Contents