Connections on the front side
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
176
of 328
7.15
Type code: from BM53XX-XXXX-XXXX-XX08
X1: Service interface
NOTE!
Only the service cable BM5-K-USB-XXX is allowed
to be used, see ZService interfaceon page 205
X2: Digital inputs/outputs *)
1:+24V (SELV/PELV)
2 to 3: BB1 On (SELV/PELV)
4 to 7: Digital output (SELV/PELV)
8: M24V (SELV/PELV)
9 to 10: BB2 On (SELV/PELV)
11: +24V (SELV/PELV)
12: M24V (SELV/PELV)
13: Fast dig. input 1 (SELV/PELV)
14: Fast dig. input 2 (SELV/PELV)
15 to 18: Digital input (SELV/PELV)
19: Dig. input 7/ pulse enable 2
20: Dig. input 8/ pulse enable 1
111
10 20
B: Add-on module (option) - not pluggable
BM53XX-XXXX-XX00 - no add-on module
BM53XX-XXXX-XX01
Add-on module IEE with external supply
BM53XX-XXXX-XX03
Add-on module SIE with internal supply
Refer to ZAdd-on moduleson page 182
BM53XX-XXXX-XXXX-01XX and
BM53XX-XXXX-XXXX-07XX
X3 EtherCAT
®
-IN X4 EtherCAT
®
-OUT
BM53XX-XXXX-XXXX-02XX
X3 VARAN-IN X4 VARAN-OUT
BM53XX-XXXX-XXXX-03XX
X3 CANopen
®
-IN X4 CANopen
®
-OUT
BM53XX-XXXX-XXXX-04XX
X3 POWERLINK
®
-IN X4 POWERLINK
®
-OUT
1: TX+ 2: TX-
3: RX+ 6: RX-
4, 5, 7, 8: reserved
A: Assembly opening additional module
The delivery status is: empty
The operation is only permitted / possible with an
additional module BM5-O-SAF-XXX (Mounting see
manual 5.09013 and/or 5.11016)
It is not allowed to plug any other modules in!