EasyManua.ls Logo

Baumuller b maXX 5000 Series - Page 179

Baumuller b maXX 5000 Series
330 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
Instruction handbook b maXX 5000
Document No.: 5.09021.16
179
of 328
7
X3 / X4 - fieldbus
connection
EtherCAT
®
Type code b maXX 5000 with EtherCAT
®
CoE profile:
BM5XXX-XXXX-XXXX-01XX
Type code b maXX 500
0 with EtherCAT
®
SoE profile:
BM5XXX-XXXX-XXXX-07XX
X3
X4
EtherCAT
®
IN
EtherCAT
®
OUT
Number of bus connections 1 IN / 1 OUT
Bus connection RJ 45
Number of parameters refer to
p
arameter handbook b maXX 5000
Data size of parameters 16 / 32 Bit
Baud rates 10 / 100 Mbit/s
X3
X4
1: TX+
2: TX-
3: RX+
4: re
served
5: re
served
6: RX-
7: re
served
8: re
served

Table of Contents