Cabling
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
248
of 328
11.1
m Motor cable with HIPERFACE DSL
®
36 A
Connect cable shield with the
housing of the connector.
Cable length
(according order)
Heat shrink tubing
Pin 1
Connect the cable shielding
via the strain relief clamp
of the connector housing.
400 mm
Data cable shielded
DSL- blue
DSL+
Pin 19 DSL-
Pin 20 DSL+
B+
B-
V
W
GN/GE
U
white
Figure 107: Motor cable with HIPERFACE DSL
®
36 A
Cable: 4G6.0+(2x1.0)+(2x22AWG)
Shielding: copper wires, tinned
Motor side:
Circular metal connector-pin speedtec
®
M40 9-pin
Outside shielding and ins
ide shielding must be wired separately.
Device side:
Metal D-sub connector 45°, 26-pin with electronics, part No. 460219
Connect inside shielding with th
e connector housing.
Circular connector
speedtec
®
M40
Type of stranding Unconnected
wires
Cross section of wire
U
 U 6 mm² / black / U
V
 V 6 mm² / black / V
W
 W 6 mm² / black / W
 GN/GE 6 mm² / green-yellow
+
B+ 1.0 mm² / black
- B- 1.0 mm² / black
H
DSL+ 22 AWG / white
L DSL- 22 AWG / blue
Housing - Outside shielding
Housing - Inside shielding

Table of Contents