Cabling
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
260
of 328
11.1
SIE The connection cable is not offered by Baumüller and must be made by the user:
1 Use the follo
wing materials:
m Ca
ble: LiYCY 2 x (2 x 0.14 mm²) + 1x0.34 mm² Cu braiding.
m D-
sub connector: 9-pin, female (SIE side)
m E.g. D-sub
connector: 26-pin, male (b maXX 5000 side)
m Ca
bles must be of twisted pair wire (DAT+/DAT-, CLK+/CLK-) from SSI encoder em-
ulation to further mast
er control systems
2 Co
nnect
m th
e cable shield with the connector shell of the D-sub male/D-sub female connector
m th
e 9-pin female connector (SIE side) with the cable
m e.g. the 2
6-pin D-sub male connector (b maXX 5000 side, pin assignment see
ZCo
nnecting cable for sine/square-wave incremental encoderon page 258) with
the other cable ending.
NOTE!
On the SSI encoder emulation side data and
clock cables (DATA+/DATA- and CLK+/
CLK-) are terminated with 120 . Additional termination resistors are required on the
CNC side if this resistors are not provided by its manufacturer.
1
5
9
8
7
1
20
19
13
3
Figure 115: Connection cable IEE with b maXX 5000