Brake resistors
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
266
of 328
11.3
The machine cycle of the application determines the further resistor data.
M
Brake
= torque of the motor when braking
P
Bake max.
1
2
---
nM
Brake
(calculation by means of drive profile)=
P
Brake rated
P
Brake max.
T
Brake
T
Cycle
----------------
=
ED %
T
Brake
T
Cycle
----------------
100 %=