Electrical data
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
64
of 328
3.4
m BM519X active mains rectifier unit
BM519
2-S BM5192-F BM5193-F
-XTXX-.. /-XIXX-.. /
-XGXX-..
Input rated power
1)
150 kVA 200 kVA
Input rated current (I
eff
)
1) 2) 3)
220 A 290 A
Distortion factor of the input current (THD
I
)
1)
6 %
Input peak current (I
eff
)
1) 2) 3)
435 A
for max. 10 s
435 A
for max. 10 s
PWM switching frequency
8 kHz
DC link voltage
power supply dependent/rated
640 V
DC
to 760 V
DC
14)
DC link capacitance (internal) 7.5 mF
DC link discharge time
(internal DC link capacitance)
9)
Approx. 600 s
Total max. connectable cap
acitance in the DC link
(internal + external)
100 mF
Connection power at DC link
1) 5)
150 kW 200 kW
Peak power at DC link
4) 6)
300 kW
for max. 10 s
Power factor (inductive only) 0.9 bis 1.0
Ready-to-operate after 50 s
Max. charge-up time 10 s
Quick discharge
10)
5 s
External brake resistor R
B
Quick discharge resistor R 10 
Power loss with regard to power supply
7)
2500 W 3300 W
Power loss with regard to control voltage supply
8)
Max. 100 W Max. 60 W