LR2000 Programming Manual V1.2
fn = 80
m = 48
0 d 255
k = (pL + pH × 256 ) - 3
[Description] Stores QR Code data (d1... dk) into the QR Code symbol storage area.
(pL + pH × 256) - 3) bytes are processed as QR Code data after m (d1...dk).
GS ( k pL pH cn fn m (cn=49, fn=81)
[Name] Print QR Code in symbol storage area
[Format] ASCII GS ( k pL pH cn fn m
Hex 1D 28 6b pL pH cn fn m
Decimal 29 40 107 pL pH cn fn m
[Range] pL = 3, pH = 0
cn = 49
fn = 81
m = 48
[Description] Print QR Code from data stored in QR code symbol storage area
User must consider QR code quiet zone (spacing of above, below, left and right of
printed QR code as specified in the QR Code specification.)
GS ( k pL pH cn fn m (cn=49, fn=82)
[Name] Request size information of QR Code in symbol storage area.
[Format] ASCII GS ( k pL pH cn fn m
Hex 1D 28 6b pL pH cn fn m
Decimal 29 40 107 pL pH cn fn m
[Range] pL = 3, pH = 0
cn = 49
fn = 82
m = 48
[Description] Request transmission of size information data of QR Code in symbol storage area.
Following information will be returned by the printer.
Information
Hex
Decimal
Data length (bytes)
Header
37
55
1
Identifier
36
54
1
Width
30 - 39
48 - 57
1 to 5
Delimiter
1F
31
1
Height
30 - 39
48 - 57
1 to 5