LR2000 Programming Manual V1.2
In setting count-up mode, the minimum value of the counter is [aL + aH ×256] and
the maximum value is [bL + bH ×256]. If counting up reaches a value exceeding
the maximum, it is resumed with the minimum value.
In setting count-down mode, the maximum value of the counter is [aL + aH ×256]
and the minimum value is [bL + bH×256]. If counting down reaches avalue less
than the minimum, it is resumed with the maximum value.
When this command is executed, the internal counter that indicates the repetition
number specified by r is cleared.
[Defaults] aL = 1, aH = 0, bL = 255, bH = 255, n =1, r = 1
[Reference] GS C 0, GS C 2, GS C ;, GS c
GS C 2 nL nH
[Name] Set counter
[Format] ASCII GS C 2 nL mH
Hex 1D 43 32 nL mH
Decimal 29 67 50 nL mH
[Range] 0 nL 255
0 nH 255
[Description] Sets the serial number counter value.
nL and nH determine the value of the serial number counter set by [nL + nH ×256].
[Notes] In count-up mode, if the counter value specified by this command goes out of the
counter operation range specified by GS C1 or GS C ;, it is forced to convert to the
minimum value by GS c.
In count-down mode, if the counter value specified by this command goes out of
the counter operation range specified by GS C1 or GS C ;, it is forced to convert to
the maximum value by GS c.
[Default] nL = 1, nH = 0
[Reference] GS C 0, GS C 1, GS C ; GS c
GS C ; sa ; sb ; sn; sr; sc;
[Name] Select count mode (B)
[Format] ASCII GS C ; sa ; sb ; sn ; sr ; sc ;
Hex 1D 43 3B sa 3B sb 3B sn 3B sr 3B sc 3B
Decimal 29 67 59 sa 59 sb 59 sn 59 sr 59 sc 59
[Range] “0” sa “65535”
“0” sb “65535”
“0” sn “255”
“0” sr “255”
“0” sc “255”