1.6 Control Box
The Control Box is mounted to the Dragon A400 at the Bend-Tech Manufacturing Facility.
Ensure the Control Box is securely mounted in its location on the rear side of the third support
leg from the front of the machine. Ensuring the Control Box is properly and securely mounted
is critical to long-term functioning of its internal components and the Dragon A400. Ensure all
cables are properly inserted and secured in their respective connectors.
To open the Control Box, use a large, at blade screwdriver to turn the Control Box
latch.
Y
A B
Z
X
Y C X
-
B A+ A-
EStop
Engraver Torch
Laser
Gate EStop EStop
Z
+ Z-
L
E
Motor Cable
Connections
Axis Sensor Cable
Connections
C-Axis Cable
Connection
Ethernet Cable
Connection
Engraver Air Line
Connection
Main Power Switch
Main Power Cord
Connection
Main Power Fuses
Air Line
Connection
Lifter Air Line
Connection
Control Box
Latch
E-Stop Cable
Connections
Green Power
Switch
15Bend-Tech Dragon A400
Start-Up and Training
Setup Inspection
01