787 Flight Crew Operations Manual
DO NOT USE FOR FLIGHT
Engines, APU -
Controls and Indicators
Copyright © The Boeing Company. See title page for details.
7.10.20 D615Z003-TBC
Fuel Control Switches
RUN –
Opens the spar fuel valve
arms the engine fuel valve (the EEC opens the valve when required)
arms the selected ignitors(s) (the EEC turns the ignitors on when required)
CUTOFF –
closes the engine fuel valve (and spar fuel valve if start switch not in
START)
removes ignitor power
unlocks the engine fire switch
Engine Control Panel
1
FUEL CONTROL Switch
L FUEL CONTROL R
RUN
CUTOFF
CONTROL STAND
1
ART TITLE
L
NORM
START
RL
R
ENGINE
EEC MODE
START
START
NORM
ALTN
NORM
ALTN
NORM
OVERHEAD PANEL
1
2
3