787 Flight Crew Operations Manual
DO NOT USE FOR FLIGHT
Fire Protection -
EICAS Messages
Copyright © The Boeing Company. See title page for details.
8.30.2 D615Z003-TBC
Cabin System EICAS Messages
Cabin
Crew Rest Area
[Option - Crew Rest]
[Option - Overhead flight crew rest]
[Option - Overhead flight attendant rest]
System Test Messages
The following messages are associated with the manually initiated fire test.
Message Level Aural Condition
SMOKE EQUIP
CLG AFT
Caution Beeper Smoke is detected in the aft equipment
cooling system.
SMOKE EQUIP
CLG FWD
Caution Beeper Smoke is detected in the forward equipment
cooling system.
SMOKE EQUIP
CLG MISC
Caution Beeper Smoke is detected in the miscellaneous
equipment cooling system.
SMOKE
L AVAT O R Y
Advisory Smoke is detected in one or more
lavatories.
Message Level Aural Condition
SMOKE REST
UPR DR 1
Caution Beeper Smoke is detected in the Overhead Flight
Crew Rest area.
SMOKE REST
UPR DR 4
Caution Beeper Smoke is detected in the Overhead Flight
Attendant Rest area.
Message Level Aural Condition
DET FIRE
WHEEL WELL
Advisory Wheel well fire detection system is failed.
FIRE TEST FAIL Warning One or more fire/overheat detection
systems have failed to successfully
complete the manually initiated
fire/overheat test.
FIRE TEST IN
PROG
Warning Fire
Bell
A manually initiated fire/overheat detection
system test is in progress.
August 14, 2009