12. ACS 752 settings
12.1 Factory setting
Menu Factory setting
Language English
Date/Time CET
Unit of measurement kg/m
Garage data empty, no data entered
Flushing enabled
Serial Number Serial number has already been
entered (compare with name
plate)
Asanetwork Service disabled
CoRe Main Menu disabled
12.2 Set unit of measurement
1. Call up start screen.
2. Press <MENU>.
3. Press <1> for "Set up".
4. Press <3> for "Unit of measurement".
5. Select unit with u and o.
6. Confirm unit with <OK>.
i Return with <ESC>.
12.3 System information
1. Call up start screen.
2. Press <MENU>.
3. Press <1> for "Set up".
4. Press <4> for "System Information".
"The display shows the information on the sw release.
i Return with <OK> or <Esc>.
12.4 Activation
Menu Factory setting
Report management Enabled
Beeper Enabled
UV Oil Manual Disabled
PAG POE Disabled
ASANETWORK
Disabled
WiFi Configuration
Disabled
CoRe Configuration Disabled
12.4.1 Report Management
i If you want to storage and then print the data of the
loaded and recovered coolant you have to enable the
“Report Management” function (see chapter 13.6).
Once all data of the loaded and recovered coolant
are enabled they are automatically stored.
1. Call up start screen.
2. Press <MENU>.
3. Press <1> for "Set up".
4. Press <6> for "Activations".
5. Select "Report management" with u and o.
6. Enable/Disable with <OK>.
i Return with <ESC>.
12.4.2 Beeper
i This function is used to enable or disable the beeper
when pressing the keys or as a warning during op-
eration.
1. Call up start screen.
2. Press <MENU>.
3. Press <1> for "Set up".
4. Press <6> for "Activations".
5. Select "Beeper" with u and o.
6. Enable/Disable with <OK>.
i Return with <ESC>.
12.4.3 UV Oil manual
i This function is used to enable or disable the manual
inclusion of oil and UV dye. If injection oil scales is
enabled, oil drain and UV dye are disabled and the
station operates in manual mode.
i Press <MENU> button to inject oil and UV dye and
visually check the level in the bottles. A series of
messages guide the operator on the proper use of
the operator station.
1. Call up start screen.
2. Press <MENU>.
3. Press <1> for "Set up".
4. Press <6> for "Activations".
5. Select "UV Oil Manual"with u and o.
6. Enable/Disable with <OK>.
i Return with <ESC>.