128 en | Keypad Installer menu Control Panels
2016.06 | 08 | F.01U.303.996 Installation and System Reference Guide Bosch Security Systems, Inc.
HTTP Port Number 80 _______________________________
IPv4 Server Address 0.0.0.0 _______________________________
IPv6 Server Address 0.0.0.0 _______________________________
Module Hostname Blank _______________________________
DHCP/AutoIP Enable
B91x/B92x keypads configuration of DHCP/AutoIP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [1] DHCP. The keypad shows the DHCP/AutoIP current
configuration.
3. Press [ENTER] to edit the DHCP/AutoIP Enable configuration for the module.
4. Use [PREV] or [NEXT] to toggle between Yes and No.
5. Press [ENTER] while viewing the desired option to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of DHCP/AutoIP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [1] DHCP. The keypad shows the DHCP/AutoIP current
configuration.
3. Press [Yes] or [No] – whichever is available – to change the programming.
4. Press [Save] to save the programming.
5. When the keypad shows Parameter Saved, escape from the menu.
UPnP Enable
B91x/B92x keypads configuration of UPnP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [2] UPnP. The keypad shows the UPnP current configuration.
3. Press [ENTER] to edit the UPnP Enable configuration for the module.
4. Use [PREV] or [NEXT] to toggle between Yes and No.
5. Press [ENTER] while viewing the desired option to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of UPnP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [2] UPnP. The keypad shows the UPnP current configuration.
3. Press [Yes] or [No] – whichever is available – to change the programming.
4. Press [Save] to save the programming.
5. When the keypad shows Parameter Saved, escape from the menu.