Control Panels Appendix | en 171
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.06 | 08 | F.01U.303.996
Octo-relay module address setting Control panel relay number ZONEX Number
On-On-On-Off-On 121– 128* 2*
* Supported by the B9512G only.
22.1.6 B901 address settings
Valid addresses for SDI2 (or SDIx in SDI2 mode)
B901 addresses Designation
B9512G 01 – 32 Doors 1- 32 (Failsafe and Failsecure selected
in control panel programming)
B8512G 01 – 08 Doors 1- 8 (Failsafe and Failsecure selected
in control panel programming)
Valid addresses for SDI (SDIx in SDI mode)
B901 addresses Designation
81 – 88 Doors 1 – 8 failsafe mode = door unlocked
91 - 98 Doors 1 - 8 fail secure = door locked
22.1.7 B91x address settings
Address Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6
1 ON OFF OFF OFF OFF OFF
2 OFF ON OFF OFF OFF OFF
3 ON ON OFF OFF OFF OFF
4 OFF OFF ON OFF OFF OFF
5 ON OFF ON OFF OFF OFF
6 OFF ON ON OFF OFF OFF
7 ON ON ON OFF OFF OFF
8 OFF OFF OFF ON OFF OFF
9 ON OFF OFF ON OFF OFF
10 OFF ON OFF ON OFF OFF
11 ON ON OFF ON OFF OFF
12 OFF OFF ON ON OFF OFF
13 ON OFF ON ON OFF OFF
14 OFF ON ON ON OFF OFF
15 ON ON ON ON OFF OFF
16 OFF OFF OFF OFF ON OFF
17 ON OFF OFF OFF ON OFF