182 en | Appendix Control Panels
2016.06 | 08 | F.01U.303.996 Installation and System Reference Guide Bosch Security Systems, Inc.
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
Test Report – System Off-
normal, Non-expanded Status
RsssE NRY Periodic Test – System
Trouble Present
1 608 00 000
Time Changed – No User
Identified
NsD07 NJT Time/Date Reset 1 625 00 000
Time Changed by Receiver
Sync
NsD07 Nid5001JT Time/Date Reset 1 625 00 F01
Time Changed by User NsD07 NidiiiiJT Time/Date Reset 1 625 00 uuu
Trouble Tspppp NriaaBTpppp Sensor Trouble 1 380 aa ppp
Unverified Event Kpppp NriaaUGpppp Cross-Zone Trouble 1 378 aa ppp
User Authority level has
changed
NsD40 NidiiiiJZiiii Local Only Local Only
User Passcode Tamper – Too
Many Attempts
NsD03 NriaJA Wrong Code Entry 1 461 aa 000
Walk Test End RsssF Nriaa/idiiiiTE Walk Test Mode Emd 3 607 aa uuu
Walk Test Start TsssF Nriaa/idiiiiTS Walk Test Mode 1 607 aa uuu
Watchdog Reset NsD09 NpiddddYW System Reset 1 305 00 000
Watchdog Reset – SDI Device
Reported identifies the
Source
NsD09 NpiddddYW System Reset 1 305 00 000
22.2.2 Device numbers (zzz, dddd)
Device number zzz data values Description
01 - 16 001 - 016 SDI Keypads 1 through 16
01 - 59 201 - 259 SDI2 Octo-Input Modules 1 through 59
01 - 59 301 - 359 SDI2 Octo-Output Modules 1 through 59
1 801 SDI2 Premises RF Module
N/A 851 - 858 RF Repeater 1 through 8
01 - 02 401 - 402 SDI2 Network Modules 1 through 2
01 - 08 501 - 508 SDI2 Power Supply Modules 1 through 8
01 - 32 901 - 932 SDI2 Keypads 1 through 32
01 - 06 155 - 160 SDI2 POPEX Modules 1 through 6
01 - 08 33 - 40 SDI Access Modules 1 through 8
01 - 32 601 - 632 SDI2 Access Modules 1 through 32
N/A 516 - 531 IP Cameras 1 through 16
OnBrd 100 Control Panel Enclosure