154 en | Keypad Installer menu Control Panels
2016.06 | 08 | F.01U.303.996 Installation and System Reference Guide Bosch Security Systems, Inc.
Replace Point RFID
B91x/B92x keypads use of Replace Point RFID
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Wireless > [1] RF Point Menu> [2] Replace Point RFID. The keypad lists any
enrolled points.
3. Use [PREV] or [NEXT] to scroll though the list of wireless points, and go to the point for
which you want to replace the device, or simply enter the point number.
4. Press [ENTER] to replace the device. The keypad instructs you to reset the new device.
5. Initiate discovery on a RADION device per the device instructions, or press the RESET
button on an Inovonics device.
6. When the keypad shows Point Enrolled, escape from the menu.
B93x/B94x keypads use of Replace Point RFID
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Wireless > [1] RF Point Menu> [2] Replace Point RFID. The keypad lists any
enrolled points.
3. Use /[PREV] or /[NEXT] to scroll though the list of wireless points, and go to the
point for which you want to replace the device, or simply enter the point number.
4. Press [ENTER] to replace the device. The keypad instructs you to reset the new device.
5. Initiate discovery on a RADION device per the device instructions, or press the RESET
button on an Inovonics device.
6. When the keypad shows Point Enrolled, escape from the menu.
20.2.3 [1] RF Point Menu> [3] Remove Point RFID
In this menu, you can remove RFID points.
Remove Point RFID
B91x/B92x keypads use of Remove Point RFID
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Wireless > [1] RF Point Menu> [3] Remove Point RFID. The keypad lists any
enrolled points.
3. Use [PREV] or [NEXT] to scroll though the list of wireless points, and go to the point you
want to remove, or simply enter the point number.
4. Press [ENTER] to remove the device. The keypad removes the device and shows Point
RFID Removed.
5. Escape from the menu.
B93x/B94x keypads use of Remove Point RFID
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Program > [1] RF Point Menu> [3] Remove Point RFID. The keypad lists any
enrolled points.
3. Use /[PREV] or /[NEXT] to scroll though the list of wireless points, and go to the
point you want to remove, or simply enter the point number.
4. Press [Remove] to remove the RFID point. The keypad removes the device and shows
Point RFID Removed.
5. Escape from the menu.

Table of Contents

Other manuals for Bosch B9512G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B9512G and is the answer not in the manual?

Bosch B9512G Specifications

General IconGeneral
ModelB9512G
ManufacturerBosch
CompatibilityBosch Security Systems
Number of Zones599
Keypads32
Communication FormatsContact ID, SIA
Input Voltage16.5 VAC
Battery Backup7 Ah
Operating Temperature0°C to +49°C (32°F to +120°F)

Related product manuals