66 en | On-board outputs Control Panels
2016.06 | 08 | F.01U.303.996 Installation and System Reference Guide Bosch Security Systems, Inc.
10 On-board outputs
The control panel provides three powered relay outputs.
10.1 Circuit protection
The powered outputs come with circuit protection.
Four self-resetting circuit breakers protect the control panel from short circuits on the
continuous and programmable power outputs.
The self-resetting circuit breakers include:
– One self-resetting circuit breaker protects Terminal 3, auxiliary power.
– Another self-resetting circuit breaker protects:
– Terminal 6. Alarm power output
– Terminal 7. Alternate alarm power output
– Terminal 8. Switched auxiliary power
Notice!
A short circuit on one terminal disrupts power to the other two terminals.
– The third self-resetting circuit breaker protects Terminals 26 and 30, power +.
– The fourth self-resetting circuit breaker protects the ZONEX connection.
Notice!
UL requires any device powered from a power output to be supervised.
10.2 Total available power
The system produces up to 1.4 A of combined power at 12.0 VDC nominal. The outputs in this
section share the available power. These outputs appear as shown on the faceplate.
Output A (1), Alarm power output
Programmable output normally open, power on alarm.
Output B (2), Alternate alarm power output
Programmable output normally open, power on alarm.
Output C (3), Switched auxiliary power
Programmable output normally closed, switches power off when the Sensor Reset command
is executed.
SDIx Power+ / R
Powers serial device interface (SDI) keypads, or use to power serial device interface 2 (SDI2)
devices, such as keypads and expansion modules.