Control Panels Appendix | en 173
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.06 | 08 | F.01U.303.996
Fail mode Central station
Modem4
SDI address setting Keypad display
LOCKED SDI #40 98 Door #8
22.1.9 SDI keypad address settings
Address Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6
1 ON ON ON ON Encoding
Tone ON/
OFF
ON
2 OFF ON ON ON ON
3 ON OFF ON ON ON
4 OFF OFF ON ON ON
5 ON ON OFF ON ON
6 OFF ON OFF ON ON
7 ON OFF OFF ON ON
8 OFF OFF OFF ON ON
9 ON ON ON OFF ON
10 OFF ON ON OFF ON
11 ON OFF ON OFF ON
12 OFF OFF ON OFF ON
13 ON ON OFF OFF ON
14 OFF ON OFF OFF ON
15 ON OFF OFF OFF ON
16 OFF OFF OFF OFF ON
22.2 Reporting and device number information
This section contains information to help you understand control panel reports.
22.2.1 Report format definitions
Notice!
Control panels using Modem4 send 4-digit Point and User data.
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
A point supervisory condition
occurred
Jspppp NriaBSpppp 24 hour Non-Burglary 1 150 aa ppp
A valid local RPS access
occurred
RsF01 NLS Successful Download/
Access
1 412 00 000
A valid remote RPS access
callback occurred
RsssF NphhhRS Successful Download/
Access
1 412 00 000