158 en | Keypad Installer menu Control Panels
2016.06 | 08 | F.01U.303.996 Installation and System Reference Guide Bosch Security Systems, Inc.
B91x/B92x keypads use of Signal Strength (for RF repeaters)
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Wireless > [3] RF Diagnostic Menu > [2] RF Repeater Menu > [1] Strength.
3. Use [PREV] or [NEXT] to scroll though the list, and go to the repeater for which you want
to view diagnostic information, or enter the repeater number.
4. Press [ENTER] to view the signal strength. The menu scrolls through the following sub-
categories, with the results of the diagnostic check: Signal Strengths, Level, Margin.
5. When finished viewing the information, escape from the menu.
B93x/B94x keypads use of Signal Strength (for RF repeaters)
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Wireless > [3] RF Diagnostic Menu > [2] RF Repeater Menu > [1] Strength.
3. Use /[PREV] or /[NEXT] to scroll though the list, and go to the repeater for which
you want to view diagnostic information, or enter the repeater number and press
[ENTER].
4. Press [Signal] to view the state. The menu scrolls through the following sub-categories,
with the results of the diagnostic check: Signal Strengths, Level, Margin.
5. When finished viewing the information, escape from the menu.
20.3 [3] Diags menu
Use the Diagnostics menu to view available diagnostics.
20.3.1 [1] Wireless
The Wireless diagnostics are presented in two different menus for your convenience. Refer to
[3] RF Diagnostic Menu > [1] RF Points, page 156 and [3] RF Diagnostic Menu > [2] RF Repeater
Menu, page 157.
20.3.2 [2] Network menu
Use the Network menu to view information about the control panel’s network connection.
Settings
B91x/B92x keypads use of Settings
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Network > (choose the bus module or on-board) > [1] Settings. The keypad
scrolls through the following sub-categories, indicating the programming for: Hostname,
iPv4 Source IP, iPv6 Source IP, MAC Address.
3. When finished viewing the information, escape from the menu.
B93x/B94x keypads use of Settings
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Network > (choose the bus module or on-board) > [1] Settings. The keypad
shows the following sub-categories, indicating the programming for: Hostname, iPv4
Source IP, iPv6 Source IP, Mac Address.
3. When finished viewing the information, escape from the menu.
Connection
B91x/B92x keypads use of Connection
1. Enter the installer passcode, and then open the [1] Installer menu.