Control Panels Keypad Installer menu | en 135
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.06 | 08 | F.01U.303.996
B93x/B94x keypads configuration of RPS Phone Number
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [3] RPS > [2] RPS Phone Number.
3. Press [Edit] to change the phone number.
4. Delete existing number, if necessary, and then enter the new number.
5. Press [ENTER] to save the phone number.
6. Press [Save] to save the programming.
7. When the keypad shows Parameter Saved, escape from the menu.
20.1.11 [3] RPS > [3] RPS IP Address menu parameters
The control panel can use a network hostname or an IPv4 address to call RPS. In this menu,
you can program the IPv4 address or hostname for RPS communication.
RPS IP Address
B91x/B92x keypads configuration of RPS IP Address
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [3] RPS > [3] RPS IP Address.
3. Press [ENTER] to edit RPS IP address.
4. Use [PREV] or [NEXT] to toggle between the option to edit the address as an IPv4
address or as a hostname. Press [ENTER] when the keypad shows the option you want to
edit.
5. Delete existing characters, if necessary, and then enter the new characters. Use [PREV]
or [NEXT] to move to a different byte (group of digits).
6. Press [ENTER] to save the programming.
7. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of RPS IP Address
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [3] RPS > [3] RPS IP Address.
3. Press [Edit as IPv4] for an IP address, or the [Edit as Name] for a hostname.
4. Delete existing characters, if necessary, and then enter the new characters. Use [PREV]
or [NEXT] to move to a different byte (group of digits).
5. For an IPv4 address, use /[PREV] or /[NEXT] to move to a different byte, and use
the number keys to enter the new numbers. For a hostname, press a number key
repeatedly to scroll through the number and letters shown on the key.
6. Press [Save] to save the programming.
7. When the keypad shows Parameter Saved, escape from the menu.
20.1.12 [3] RPS > [4] RPS Port Number menu parameters
In this menu, you can specify the destination port for outgoing RPS session requests to the
specified IP address.
RPS Port Number
B91x/B92x keypads configuration of RPS Port Number
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [3] RPS > [3] RPS Port Number.
3. Press [ENTER] to edit RPS port number.
4. Delete the existing number, if necessary, and then enter the new number.
5. Press [ENTER] to save the programming.