2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[3] DNS Parameters > [1] IPv4 Server Address. The keypad shows the IPv4 Server
Address current configuration.
3. Press [ENTER] to edit the IPv4 Server Address.
4. Delete the existing number, if necessary, and then enter the new number. Use [PREV] or
[NEXT] to move to a different byte.
5. Press [ENTER] to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of IPv4 Server Address
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[3] DNS Parameters [1] IPv4 Server Address. The keypad shows the DHCP/AutoIP current
configuration.
3. Press [IPv4 Server Address] to edit the IP address.
4. Delete the existing number, if necessary, and then enter the new number. Use /[PREV]
or /[NEXT] to move to a different byte.
5. Press [Save] to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
IPv6 Server Address
B91x/B92x keypads configuration of IPv6 Server Address
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[3] DNS Parameters > [2] IPv6 Server Address. The keypad shows the IPv4 Server
Address current configuration.
3. Press [ENTER] to edit the IPv6 Server Address.
4. Delete the existing number, if necessary, and then enter the new number. Use [PREV] or
[NEXT] to move to a different byte.
5. Press [ENTER] to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of IPv6 Server Address
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[3] DNS Parameters > [2] IPv6 Server Address. The keypad shows the DHCP/AutoIP
current configuration.
3. Press [IPv6 Server Address] to edit the IP address.
4. Delete the existing number, if necessary, and then enter the new number. Use /[PREV]
or /[NEXT] to move to a different byte.
5. Press [Save] to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
Module Hostname
B91x/B92x keypads configuration of Module Hostname
1. Enter the installer passcode, and then open the [1] Installer menu.