| 1 689 989 298 2017-03-08Robert Bosch GmbH
Technical data | FSA 760 Edition | 27
8. Technical data
8.1 Measuring functions
8.1.1 Engine test
Measuring functions Measuring ranges Resolution Sensors
Speed 450 min
‑1
– 6000 min
‑1
100 min
‑1
– 12000 min
‑1
250 min
‑1
– 7200 min
‑1
100 min
‑1
– 500 min
‑1
10 min
‑1
10 min
‑1
10 min
‑1
10 min
‑1
Connecting cable B+/B–
Trigger clamp, Secondary sensor,
Primary connecting cable (UNI 4)
Current clamp 30A, Diesel clip‑on sensor,
Current clamp 1000 A (starter current)
Oil temperature ‑20 °C – 150 °C 0,1 °C Oil temperature sensor
U‑battery 0 – 60 V 0,1 V Connecting cable B+/B–
U terminal 15 0 – 60 V 0,1 V Primary connecting cable (UNI 4)
U terminal 1 0 – 20 V 50 mV Primary connecting cable (UNI 4)
Ignition voltage,
Spark voltage
±500 V
±50 kV
1 V
100 V
Primary connecting cable (UNI 4),
Secondary sensor
Spark duration 0 – 6 ms 0,01 ms Primary connecting cable (UNI 4),
Secondary sensor
Relative compression via starter current 0 – 200 Ass 0,1 A Primary connecting cable (UNI 4),
Secondary sensor
U alternator ripple 0 – 200 % 0,1 % Multi measuring cable CH1
I starter
I Alternator
I Spark plugs
0 – 1000 A 0,1 A Current clamp 1000 A
I Primary 0 – 30 A 0,1 A Current clamp 30 A
Closing angle 0 – 100 %
0 — 360 °
0,1 %
0.1 °
Primary connecting cable (UNI 4)
Closing time 0 – 50 ms 0,01 ms
0,1 ms
Secondary sensor
Current clamp 30 A
Ignition point,
Ignition advance with stroboscope
0 – 60 °KW 0,1 °KW Trigger clamp
Start of delivery, Start of injection,
Injection timing
with stroboscope
0 – 60 °KW 0,1 °KW Clip‑on sensor
Pressure (air) ‑800 hPa – 1500 hPa 1 mbar Air pressure sensor
Pulse‑duty factor t‑/T 0 – 100 % 0,1 % Multi measuring cable CH1 / CH2
Injection time 0 – 25 ms 0,01 ms Multi measuring cable CH1 / CH2
Glow time 0 – 20 ms 0,01 ms Multi measuring cable CH1 / CH2
8.1.2 Multimeter
Measuring functions Measuring ranges Resolution Sensors
Speed as for engine test
U battery 0 ‑ 60 V 0,01 V Connecting cable B+/B–
U term. 15 0 – 60 V DC
1)
0,1 V Primary connecting cable (UNI 4)
U‑DC
min./max.
±200 mV – ±20 V
±20 V – ±200 V
1)
0,001 V
0,01 V
Multi measuring cable CH1 / CH2
I‑1000 A ±1000 A 0,1 A Current clamp 1000 A
I‑30 A ±30 A 0,01 A Current clamp 30 A
Resistance
(R Multi 1)
0 – 1000 Ω
1 kΩ – 10 kΩ
10 kΩ – 999 kΩ
0,001 Ω
0,1 Ω
100 Ω
Multi measuring cable CH1
Pressure P‑air 0,2 hPa – 2500 hPa 0,1 hPa Air pressure sensor
Oil temperature ‑20 °C – 150 °C 0,1 °C Oil temperature sensor
Air temperature ‑20 °C – 100 °C 0,1 °C Air temperature sensor
Fluid pressure 0 – 10000 hPa 10 hPa Fluid pressure sensor,
Oil pressure sensor
1)
The measuring range is greater than the permissible measurement voltage