7-1
Bosch Security Systems 05/10 BLCC100I
SE CT IO N 7

T
he Solution 16
plus
is capable of controlling up to 16 inputs
in either hardwire or wireless conguration. Each input can
have its own unique name up to 16 characters to identify it on
the system for display and reporting purposes.
Under the commands menu you are able to view the status of
any input, bypass a zone, dene which zones will operate in
chime mode, dene which zones operate in part 2 mode and
reset smoke detectors.
There is a command called Zone Array that allows the installer
to view the condition of inputs in banks of 16. This is extremely
helpful when commissioning a system or fault nding.
There are numerous congurations for each hardwire input. The
end of line resistor can be congured to eliminate the need to
change the end of line resistors on a job when doing a change
over. Input zones can be setup as alarm only, alarm + tamper or
even split end of line.
For normally open contacts the system is wired exactly the
same as for normally closed but there is an option provided that
inverts the sealed state of a zone.
When arming the system, all zones will be tested by default and
you may wish to turn this option o for certain zones so that you
don’t continually alert the operator during arming.
The sensor watch feature lets you monitor zones to ensure that
they are working and detecting movement within a determined
programmable period.
Zones by default can be bypassed and you should disable
this option for zones you don’t want to be able to bypass, for
example 24hr, re, holdup or panic zone types.
The PGM input is a special input that can be congured to accept
data from a number of dierent RF receiver manufacturers or
simply be used as an keyswitch input.
The tamper options congure the system behaviour for cabinet
tamper alarms and also for the cabinet tamper of the peripheral
devices.
Device
Address SW
1 2 3
Single EOL
Zones
Physical Zone
Numbering
Alarm + Tamper
Zones
Physical Zone
Numbering
Split EOL
Zones
Physical Zone
Numbering
Solution Panel --- 8 1 to 8 8 1 to 8 16 1 to 16
CM104B Expander OFF OFF OFF 8 9 to 16 8 9 to 16
Total Zones 16 16 16
Table 20: Zone Conguration