7-10
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Input Programming
Inputs > RF Zone >
Test RF Device
MENU 3-3-2
This menu allows you to test just how good the current position
is for an RF device. Enter the command and you will be presented
with a list of RF zones in the current area that are available for
test. Use the arrow keys to highlight the zone to test and press
OK. At any time press menu to exit.
1) Press [MENU] + [3] + [3] + [2] and use the up and down arrows
to highlight the zone you want to test in the list and press [OK].
Alternatively, you can enter the zone number directly and
press [OK]. The system will only list RF zones in the current
area.
Zn002 Zone 2 Name
Waiting For Trigger
Press OK or MENU
2) Once a signal is received the following information will be
displayed.
Zn002 Zone 2 Name
Transmission = 001
Signal = Good
Press OK or MENU
Signal can = Good, Average or Relocate
Every time you send a transmission, the number of transmissions
will increment and the average of the signals with be displayed.
Be sure to send a few transmissions to establish a more accurate
signal measurement.
GLO B AL IN PUT OP TIO NS
Inputs > Global Input Options >
EOL Value
MENU 3-4-0
0 = No EOL 5
1 = 1K0 6 = 4K7 11 = 6K8 with Tamper (2K2)
2 = 1K5 7 = 5K6 12 = 10K with Tamper (10K)
3 = 2K2 8 = 6K8 13 = 22K
4 = 2K7 9 = 8K1 14 = 3K3 with Tamper (6K8)
5 = 3K3 10 = 10K 15 = Split EOL (Parallel)
(3K3 = Primary, 6K8 = Secondary)
This menu programs the End Of Line resistor (EOL) value that
is global for all hard-wired zones including zones on the Zone
Expander Module. Only one EOL Value can be programmed.
Setting the EOL Value to type 0 to 14 will congure the system
as 8 hardwired zones . Additional zones via optional zone
expander boards will start on zone 9. Setting the EOL as type 15
will congure the system as 16 hardwired zones
1) Press [MENU] + [3] + [4] + [0]. The keypad will display the
current EOL value (Default = 5).
EOL Value
05 - 3k3 Ohm
Press 0-9 OK to SAVE
2) Use the up and down arrows to select the EOL Value you want
to use then press [OK] to save and exit or press [MENU] to exit
without saving.
Inputs > Global Input Options >
Keyswitch Options
MENU 3-4-1
0 = Latching - All On/Off 5 = Momentary All On/Off 0
1 = Latching - All On 6 = Momentary - All On
2 = Latching Part On/Off 7 = Momentary - Part On/Off
3 = Latching - Part On 8 = Momentary - Part On
4 = Latching Off 9 = Momentary - Off
(*** System Wide Parameter ***)
This menu programs the properties for any zone in the system
programmed as a keyswitch zone. Only one option can be
selected for the entire system which means that all keyswitches
tted will behave the same way.
The system can send Open and Close reports based on the
keyswitch operation with the zone number representing the
user number in the report.
1) Press [MENU] + [3] + [4] + [1]. The keypad will display the
current keyswitch options (Default = 0 Disabled).
Keyswitch Options
00 - Latching All On/Off
Press 0-9 OK to SAVE
2) Use the up and down arrows to select the required keyswitch
option then press [OK] to save and exit or press [MENU] to exit
without saving.
Inputs > Global Input Options >
Input Options
MENU 3-4-2
1 Tamper On Short N
2 Reserved N
3 Response Time 500ms N
4 Reserved N
5 Keyswitch Open/Close N
6 Alarm On Tamper N
7 Reserved N
8 Reserved N
(*** System Wide Parameter ***)
This menu programs the various global input options which will eect
all zones on the system.
1) Press [MENU] + [3] + [4] + [2]. The keypad will display the
current input options.