Installation Manual Device Programming
PIN Arming Not Allowed
Situations may arise where a keypad is only required for door access.
In this situation, to prevent a user the ability to turn the area that the
keypad has been assigned to on or o, programming this option will
still allow the user to operate the door strike that have the appropriate
access group level.
Installer PIN Arming Not Allowed
This option prevents the installer PIN to access menus or to turn the
system on or o at any keypad programmed with this option.
Show Alarm When Armed
This option allows the keypad to display which zone registered an
alarm when the area is turned on. The keypad will scroll all zones one
at a time if multiple zones registered an alarm.
Devices > Keypads >
Emergency Keys
MENU 6-1-6
1 Audible Keypad Fire Y
2 Report Keypad Fire Y
3 Audible Keypad Medical Y
4 Report Keypad Medical Y
5 Audible Keypad Panic (Invisible If Not Set) N
6 Report Keypad Panic N
7 Reserved N
8 Reserved N
The above options can be congured independantly for each
keypad tted to the system.
1) Press [MENU] + [6] + [1] + [6] and use the up and down arrows
to highlight the keypad in the list then press [OK].
Audible Keypad Fire
Report Keypad Fire
Audible Kpad Medical
Press OK ON OFF MENU
2) Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
3) Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Software Version 1.02 and higher will now display keypad
generated alarms in alarm memory.
Audible Keypad Fire
Setting this option allows the panel to sound an audible alarm when a
Keypad Fire Emergency Alarm has been triggered via the keypad. To
initiate a re emergency via the keypad, press and hold the [4] + [6]
keys down for two seconds. Enter a valid user PIN to reset the alarm
condition.
Report Keypad Fire
Setting this option allows the panel to send a Fire report to the base
station when a Keypad Fire Emergency Alarm has been triggered via
the keypad.
Audible Keypad Medical
Setting this option allows the panel to sound an audible alarm when a
Keypad Medical Emergency Alarm has been triggered via the keypad.
To initiate a medical emergency via the keypad, press and hold the
[7] + [9] keys down for two seconds. Enter a valid user PIN to reset the
alarm condition.
Report Keypad Medical
Setting this option allows the panel to send a Medical report (event
43) to the base station when a Keypad Medical Emergency Alarm has
been triggered via the keypad.
Audible Keypad Panic
Setting this option allows the panel to sound an audible alarm when a
Keypad Panic Emergency Alarm has been triggered via the keypad. To
initiate a panic emergency via the keypad, press and hold the [1] + [3]
keys down for two seconds. Enter a valid user PIN to reset the alarm
condition.
If this option is disabled, a keypad panic alarm will not be visible
on the keypad display (i.e. Invisible Panic Alarm).
Report Keypad Panic
Setting this option allows the panel to send a Panic report to the base
station when a Keypad Panic Emergency Alarm has been triggered via
the keypad.
New Software Version 1.02 and higher introduces a new method
for initiating a Keypad Fire, Keypad Medical or Keypad Panic
emergency alarms. These are shown below:
Figure 22: Keypad Emergency Keys
The new methods are easier for the end user to remember
and also allow for labelling to be applied to the keypad further
simplifying operation. At this time both old and new methods
function.
NEW K EYPAD EMERGE NCY ALAR M TR IGG ER ’S
Key Sequence Event Triggered
Ë + Ê Hold for 2 seconds
Keypad Fire Alarm
Ê + È Hold for 2 seconds
Keypad Panic Alarm
È + Â Hold for 2 seconds
Keypad Medical Alarm
Table 28: Keypad Emergency Keys