Maintenance: Settings and adjustments
58 Silver FC 00 511
ADJUSTING THE SCANFORM™
Preliminary notes
To adjust the Scanform™, you are directed to confirm or change the displayed values.
Example:
R40.01
The displayed values correspond to the last values memorized.
These values can be changed when they appear in brighter color.
Two cases:
Case 1 The displayed value(s) correspond(s) to that (those) of your adjustment tool
Select directly
.
Result:
the adjustment starts.
Case 2 The value, or at least one of the two values, does not correspond to that
of the adjustment tool.
1. Press the keys
and/or in order to display the value engraved on the
adjustment tool.
2. Press the
key to confirm the displayed value.
Note : If you erroneously confirm an incorrect pattern size, cancel your
action by selecting
.
Result:
You leave the adjustment in progress and return to the first
Scanform™ adjustment screen. Enter or confirm the values again.
3. Start the procedure again if you need to change another value.
4. When the value(s) of the tool has (have) been confirmed, press the
key
to start the gain adjustment.
Result:
the adjustment starts.
Note :
It is impossible to interrupt an adjustment in progress. When the movement of the
adjustment in progress stops, select
.
Result: You leave the adjustment in progress and return to the first Scanform™ adjustment
screen. Enter or confirm the values again.