The following Syslog message is generated as a result of a failover.
SWITCHOVER COMPLETED - by active CPU failure - Mgmt Module in slot
slotnum
is now Active
Displaying diagnostic information
Use the following commands to display diagnostic information for a hitless switchover or failover.
device#show ipc
Version 6, Grp 0, Recv: stk-p0: 840918, p1: 0, sum: 840918
Message types have callbacks:
1:Reliable IPC mesage 2:Reliable IPC atomic 4:fragmentation,jumbo
20:SYNC dynamic change 22:SYNC download reply 24:SYNC download spec i
25:SYNC restart download 26:SYNC verification 27:SYNC disable/enable
29:SYNC mgmt hello 35:IPC Ready Msg 36:IPC Msg for Sync Fra
38:SYNC reliable
Send message types:
[1]=815798, [21]=1, [35]=1, [38]=24442,
Recv message types:
[1]=816446,0, [20]=2,0 [22]=1,0
[29]=25,0, [38]=24442,0,
Statistics:
send pkt num : 840242, recv pkt num : 840918
send msg num : 840242, recv msg num : 840918,
send frag pkt num : 0, recv frag pkt num : 0,
pkt buf alloc : 832113,
Reliable-mail send success receive time us
target ID 0 0 0 0
target MAC 0 0 0 0
There is 0 current jumbo IPC session
Possible errors:
***recv msg no callback 2, last msg_type=20, from stack0, e1/9
Syntax:show ipc
device#show ipc_stat
Total available Hsync channel space = 1048580
Total available Appl channel space = 524292
Total number of application msgs in dyn queue = 0
Total number of hsync msgs in dyn queue = 0
Total number of rel sync msgs in dyn queue = 0
Total number of rx pkt msgs in standby dynamic queue
Total number of rx pkt msgs in active dyn queue = 0
Total number of rx pkts relayed = 0
Total number of rx pkts received = 5686578
Total number of dyn-sync messages received so far = 3
Total number of rel-sync pending complete = 0
Total number of L3 baseline-sync packets = 655
Total number of packet drops in sync = 0
Is image_sync_in_progress? = 0
Total num of rx dyn queue drops = 0
Total num of jumbo corrupts = 0
Total number of messages in IP send queue = 0
Syntax: showipc_stat
Displaying management redundancy information
Enter the following command at any level of the CLI, to view the redundancy parameter settings and
statistics.
Brocade(config)# show redundancy
=== MP Redundancy Settings ===
Displaying diagnostic information
132 FastIron Ethernet Switch Administration Guide
53-1003625-01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron and is the answer not in the manual?

Brocade Communications Systems FastIron Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron
CategorySwitch
LanguageEnglish

Related product manuals