NOTE
The boot images are applicable to the listed devices only and are not interchangeable. For example,
you cannot load FCX boot or flash images on an FSX device, and vice versa.
Software image files TABLE 11
Product Boot image Flash image
FSX 800
FSX 1600
sxzxxxxx.bin SXLSxxxxx.bin (Layer 2) or
SXLRxxxxx.bin (full Layer 3)
FCX
ICX 6610
grzxxxxxx.bin FCXSxxxxx.bin (Layer 2) or FCXRxxxxx.bin (Layer 3)
ICX 6430
ICX 6450
kxzxxxxx.bin ICX64Sxxxxx.bin (Layer 2) or
ICX64Rxxxxx.bin (Layer 3 - ICX 6450 only)
ICX 6650 fxzxxxxx.bin ICXRxxxxx.bin
ICXSxxxxx.bin
ICX 7250
ICX 7450
spzxxxxx.bin SPSxxxxx.bin (Layer 2) or
SPRxxxxx.bin (Layer 3)
ICX 7750 swzxxxxx.bin SWSxxxxx.bin (Layer 2) or
SWRxxxxx.bin (Layer 3)
Flash timeout
The operations that require access to the flash device are expected to be completed within the default
flash timeout value of 12 minutes.
If the operations exceed the timeout value, the flash device will be locked and further flash operations
cannot be processed. To facilitate prolonged flash operations without the device being locked, you can
manually configure the flash timeout for a longer duration using the flash-timeout command. You can
configure the flash timeout to a value from 12 through 60 minutes. The new timeout value is applicable
for all flash operations and will be effective from the next flash operation.
Software upgrades
For instructions about upgrading the software, refer to the FastIron Ethernet Switch Software Upgrade
Guide.