Supply Voltage Low alarm 7148
Supply Voltage High warning 8ca0
Supply Voltage Low warning 7530
TX Bias High alarm 7530 60.000 mA
TX Bias Low alarm 01f4 1.000 mA
TX Bias High warning 61a8 50.000 mA
TX Bias Low warning 05dc 3.000 mA
TX Power High alarm 1f07 -001.0001 dBm
TX Power Low alarm 02c4 -011.4996 dBm
TX Power High warning 18a6 -001.9997 dBm
TX Power Low warning 037b -010.5012 dBm
RX Power High alarm 2710 000.0000 dBm
RX Power Low alarm 0028 -023.9794 dBm
RX Power High warning 1f07 -001.0001 dBm
RX Power Low warning 0032 -023.0102 dBm
Syntax:show optic threshold port
For Temperature, Supply Voltage, TX Bias, TX Power, and RX Power, values are displayed for each of
the following four alarm and warning settings: High alarm, Low alarm, High warning, and Low warning.
The hexadecimal values are the manufacturer internal calibrations, as defined in the SFF-8472
standard. The other values indicate at what level (above the high setting or below the low setting) the
system should send a warning message or an alarm. Note that these values are set by the
manufacturer of the optical transceiver, and cannot be configured.
Syslog messages for optical transceivers
The system generates Syslog messages for optical transceivers in the following circumstances:
• The temperature, supply voltage, TX Bias, TX power, or TX power value goes above or below the
high or low warning or alarm threshold set by the manufacturer.
• The optical transceiver does not support digital optical monitoring.
• The optical transceiver is not qualified, and therefore not supported by Brocade.
For details about the above Syslog messages, refer to Syslog messages for optical transceivers.
FastIron Fiber-optic Transceivers
The fiber-optic transceivers listed in the following table are supported on all FastIron devices.
FastIron fiber-optic transceivers TABLE 32
Label Type Brocade part number Supports Digital
Optical Monitoring?
E1MG-BXD 1000Base-BXD 33005-000 No
E1MG-BXU 1000Base-BXU 33006-000 No
E1MG-LHA-OM 1000Base-LHA 33212-100 Yes
E1MG-LX-OM 1000Base-LX 33211-100 Yes
E1MG-100FX-LR-OM 100Base-FX-LR, 40 km 33226-100 Yes
E1MG-100FX-OM 100Base-FX 33224-100 Yes
Syslog messages for optical transceivers
FastIron Ethernet Switch Administration Guide 225
53-1003625-01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron and is the answer not in the manual?

Brocade Communications Systems FastIron Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron
CategorySwitch
LanguageEnglish

Related product manuals