Resetting LLDP statistics
To reset LLDP statistics, enter the clear lldp statistics command at the Global CONFIG level of the
CLI. The Brocade device will clear the global and per-port LLDP neighbor statistics on the device (refer
to Displaying LLDP statistics on page 210).
device#clear lldp statistics
Syntax: clear lldp statistics [ ports ethernet port-list | all ]
If you do not specify any ports or use the keyword all , by default, the system will clear lldp statistics on
all ports.
Clearing cached LLDP neighbor information
The Brocade device clears cached LLDP neighbor information after a port becomes disabled and the
LLDP neighbor information ages out. However, if a port is disabled then re-enabled before the neighbor
information ages out, the device will clear the cached LLDP neighbor information when the port is re-
enabled.
If desired, you can manually clear the cache. For example, to clear the cached LLDP neighbor
information for port e 20, enter the following command at the Global CONFIG level of the CLI.
device#clear lldp neighbors ports e 20
Syntax: clear lldp neighbors [ ports ethernet port-list | all ]
If you do not specify any ports or use the keyword all , by default, the system will clear the cached
LLDP neighbor information for all ports.
Resetting LLDP statistics
FastIron Ethernet Switch Administration Guide 215
53-1003625-01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron and is the answer not in the manual?

Brocade Communications Systems FastIron Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron
CategorySwitch
LanguageEnglish

Related product manuals