Network Monitoring
Basic system management........................................................................................... 229
RMON support.............................................................................................................. 240
sFlow.............................................................................................................................245
Utilization list for an uplink port..................................................................................... 263
Basic system management
The following sections contain procedures for basic system management tasks.
Viewing system information
You can access software and hardware specifics for a Brocade Layer 2 switch or Layer 3 switch. For
software specifics, refer to the section Software versions installed and running on a device on page 90
in the FastIron Ethernet Switch Administration Guide.
To view the software and hardware details for the system, enter the show version command. The
following shows example output.
NOTE
The output may vary depending on the device on which you run the show version.
device# show version
==========================================================================
Active Management CPU [Slot-9]:
SW: Version 04.3.00b17T3e3 Copyright (c) 1996-2008 Brocade Communications, Inc.,
Inc.
Compiled on Sep 25 2008 at 04:09:20 labeled as SXR04300b17
(4031365 bytes) from Secondary sxr04300b17.bin
BootROM: Version 04.0.00T3e5 (FEv2)
HW: ANR-Chassis FastIron SX 1600-PREM (PROM-TYPE SX-FIL3U)
Serial #: TExxxxxxxx
==========================================================================
SL 3: SX-FI424C 24-port Gig Copper
Serial #: CYxxxxxxxxx
P-ASIC 4: type 00D1, rev D2 subrev 00
P-ASIC 5: type 00D1, rev D2 subrev 00
==========================================================================
SL 9: SX-FI8GMR4 8-port Management
Serial #: CHxxxxxxxx
P-ASIC 16: type 00D1, rev D2 subrev 00
==========================================================================
SL 14: SX-FI42XGW 2-port 10G LAN/WAN
Serial #: Invalid
P-ASIC 26: type 01D1, rev 00 subrev 00
P-ASIC 27: type 01D1, rev 00 subrev 00
==========================================================================
Active Management Module:
660 MHz Power PC processor 8541 (version 32/0020) 66 MHz bus
512 KB boot flash memory
16384 KB code flash memory
512 MB DRAM
The system uptime is 2 minutes 13 seconds
The system : started=warm start reloaded=by "reload"
FastIron Ethernet Switch Administration Guide
229
53-1003625-01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron and is the answer not in the manual?

Brocade Communications Systems FastIron Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron
CategorySwitch
LanguageEnglish

Related product manuals