• sysmon fa error-count on page 271
• sysmon fa link on page 272
• show sysmon counters on page 278
• show sysmon logs on page 278
• show sysmon config on page 282
sysmon fa error-count
Configures how sysmon handles fabric adaptor-related errors. The no version of this command disables
system monitoring on fabric adaptors.
Syntax
sysmon fa error-count { threshold events polling-interval | log-backoff value | action { none |
syslog } }
no sysmon fa error-count
Parameters
threshold
Defines the threshold for errors. The threshold is defined as N/W, where N is the number of
events, and W is the number of consecutive polling periods. When the threshold is reached,
actions configured for this event type will take place. Note that a threshold of 1/W implies
that there is no threshold, and the action will always be triggered.
events
Specifies the threshold in terms of the number of events. Valid values are 1 through
10.
polling-interval
Specifies the number of polling windows. The device polls the internal registers at the
interval specified by the sysmon timer value. Valid values 1-32. However, the polling
window number must be equal or greater than the number of events.
log-backoff
If an error condition persists, it will be continuously logged (internally and/or externally to
syslog as defined by the action). The log back-off count skips configured number of logs
before logging again.
action
Specifies the action to take when a fabric adapter error count exceeds the specified
threshold and log back-off values.
none
The error is logged in the internal sysmon logs. This is the default value.
syslog
The error is logged to syslog.
Modes
Global configuration mode.
Usage Guidelines
This command is supported only on FSX devices.
sysmon fa error-count
FastIron Ethernet Switch Administration Guide 271
53-1003625-01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron and is the answer not in the manual?

Brocade Communications Systems FastIron Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron
CategorySwitch
LanguageEnglish

Related product manuals