Examples
The following example configures the sysmon options for fabric adaptor links:
Brocade(config)# sysmon fa link threshold 3 7
Brocade(config)# sysmon fa link action syslog
Brocade(config)# sysmon fa link log-backoff 15
System monitoring for Cross Bar
On FSX devices, errors typically detected in the cross bar include:
• Bad (IP) headers
• Bad length errors
• Reformat errors
Besides the error count, sysmon also checks for connectivity of SFM/XBAR links. This happens at the
interval defined by the sysmon-timer command generally or specifically for cross bar.
Use the following commands to configure and display the statistics of cross bar or switch fabric module:
• sysmon xbar error-count on page 273
• sysmon xbar link on page 274
• show sysmon logs on page 278
• show sysmon counters on page 278
• show sysmon config on page 282
• show sysmon system sfm on page 283
sysmon xbar error-count
Configures system monitoring for cross bar errors. The no form of this command resets the parameters
to default values.
Syntax
sysmon xbar error-count { threshold events polling-interval | log-backoff value | action { none |
syslog } }
no sysmon xbar error-count
Parameters
threshold
Defines the failure threshold for the cross bar error-count event. The threshold is defined as
N/W, where N is the number of events, and W is the number of consecutive polling periods.
When the threshold is reached, actions configured for this event type will take place. Note
that a threshold of 1/W implies that there is no threshold, and no event will be triggered.
events
Specifies the threshold in terms of the number of events. Valid values are 1 through
10.
polling-interval
Specifies the number of polling windows. The device polls the internal registers at the
interval specified by the sysmon timer value. Valid values 1-32. However, the polling
window number must be equal or greater than the number of events.
log-backoff
System monitoring for Cross Bar
FastIron Ethernet Switch Administration Guide 273
53-1003625-01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron and is the answer not in the manual?

Brocade Communications Systems FastIron Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron
CategorySwitch
LanguageEnglish

Related product manuals