Flow control configuration notes
• Auto-negotiation of flow control is not supported on 10 Gbps and 40 Gbps ports, fiber ports, and
copper or fiber combination ports.
• When any of the flow control commands are applied to a port that is up, the port will be disabled and
re-enabled.
• For 10 Gbps and 40 Gbps ports, the show interface command with the appropriate parameters
shows whether Flow Control is enabled or disabled, depending on the configuration.
• When flow-control is enabled, the hardware can only advertise PAUSE frames. It does not advertise
Asym.
• On ICX 7750 devices the default packet-forwarding method is cut-through, in which port flow control
(IEEE 802.3x) is not supported but priority-based flow control (PFC) is supported. You can configure
the store-and- forward command in global configuration mode to enable the store-and-forward
method for packet-forwarding.
NOTE
You must save the configuration and reload for the change to take effect. See the description of the
store-and-forward command in the FastIron Command Reference for more information.
Disabling or re-enabling flow control
You can configure the Brocade device to operate with or without flow control. Flow control is enabled by
default globally and on all full-duplex ports. You can disable and re-enable flow control at the Global
CONFIG level for all ports. When flow control is enabled globally, you can disable and re-enable it on
individual ports.
To disable flow control, enter the no flow-control command.
device(config)# no flow-control
To turn the feature back on, enter the flow-control command.
device(config)# flow-control
Syntax: [no] flow-control
NOTE
For optimal link operation, link ports on devices that do not support 803.3u must be configured with like
parameters, such as speed (10,100,1000), duplex (half, full), MDI/MDIX, and Flow Control.
Negotiation and advertisement of flow control
By default, when flow control is enabled globally and auto-negotiation is ON, flow control is enabled and
advertised on 10/100/1000M ports. If auto-negotiation is OFF or if the port speed was configured
manually, then flow control is not negotiated with or advertised to the peer. For details about auto-
negotiation, refer to Port speed and duplex mode modification on page 58.
To disable flow control capability on a port, enter the following commands.
device(config)
# interface ethernet 0/1/21
device(config-if-e1000-0/1/21)# no flow-control
Flow control configuration notes
FastIron Ethernet Switch Administration Guide 65
53-1003625-01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron and is the answer not in the manual?

Brocade Communications Systems FastIron Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron
CategorySwitch
LanguageEnglish

Related product manuals